Furnace Oil Filter

QUESTION:

My home has a 1994 100,000 Btu Multi-poise Oil Furnace (Inter-City products) Last maintenance was performed in Dec.(Set flame with Digital Volt Meter, Set draft over fire, Air filter change) Yesterday I discovered that the heat exchanger was full of soot (about 80%). The only reason I noticed was the black smoke coming out of the chimney, no other symptoms was observed. The furnace has a Beckett Burner, and I was told that the nozzle should be replaced yearly. The oil filter has not been changed in two years.

ANSWER:

I thought that might catch someones eye!. If you shunt the two wires for the flame sensor within ten seconds of start-up, you attach a vom to the two (yellow) wires and set the air adjustment til you reach 300 ohms. This is supposed to be the ideal fuel/air mixture. It seems to have worked very well since the furnace was installed.


Submit your comment or answer