Hydro Flame Furnace Repair

QUESTION:

I have a hydro flame furnace in which the exhaust vent (pipe) has become badly rusted. It has begun to break up at the outside. Advice thus far is that I will need to replace the entire furnace. I find it difficult to believe that these units have been built in a way that one cannot separately replace just the exhaust tube. Anyone have an occassion to perform this task? Is it do-able?

ANSWER:

If you're talking about the exhaust tube "sleeve" that is attached to the vent assembly then it is replacable. If you are talking about the inner tube, then it is not. The inner tube is welded to the combustion chamber and is not replacable. If the inner tube isn't to far gone, the exhaust vent assemblies come in a couple different lengths and replacing with a longer one may give you enoug overlap for safe operation.