Nordyne Gas Furnace

QUESTION:

Defective manifold weldment on Miller (Nordyne) furnace. Angle wrong- causing offset in flame on cone weldment- causing burn-away of cone weldment (flame spreader) support- which then causes ignitor to fail.
Furnace- Miller CMF 80 PG DI N
Purchased furnace 11/94 Above happened 11/96 and was taken care of by Nordyne.
Happened again Winter 2000. Nordyne refused to take care of it. Out of warranty.
(ignitor and flame spreader went again)
Yes, furnace was out of warranty but this was a factory caused defect- and if it were not for a sharp gas company technician- I would have never known. They tried to get Nordyne or the distributer to look at the assembly and offer some adjustment but it was denied.
The gas company went as far as charging just their cost of the assemenly- whole assembly was replaced. Yet, Nordyne accepts no responsibility for a factory defect.
Nordyne's "customer relations" rep was caustic- admitted he knew nothing about the technical issues- would not pass me on to someone who was knowledgeable.
So, that was that. However, if you have a Miller mobile home gas furnace that likes to eat ignitors, have the serviceman check the gas feed tube ( manifold weldment) to see if it's angle is right. If it's not hopefully you will have some remaining warranty- otherwise Nordyne will NOT acknowledge a defect.

ANSWER:

Just a little "add-on" info. depending on the burner model, the ends only are replaceable which saves "a lot" of $$$$$$ versus replacing the whole assembly.